Site Analyzers

Bird's SA-XT Site Analyzers® are easy to operate and field ready for novice, occasional and experienced users. Applications include 3G, Broadcast, Government, Tactical Military, Microwave, Paging, Public Safety, Trunking, WLAN and WLL, and TETRA. SA-XT Series Site Analyzers utilize USB communication ports to link up to PC/application, field sensors and printers.

SA-6000XT

Features

  • Easy to operate and field ready for novice, occasional and experienced users.

  • Other applications include 3G, Broadcast, Government, Tactical Military, Microwave, Paging, Public Safety, Trunking, WLAN and WLL, and TETRA.

  • Color display is clearly visible in direct sunlight.

  • With a single download you can view data as Distance to Fault or Measurement Match - no need to store two traces.

  • FDR (Frequency Domain Reflectometry) measurement results in a highly reliable assessment of the health of critical components in your system; ultimately providing a “heads-up” before a failure occurs.

  • Fault location (DTF) mode indicates VSWR or Return Loss levels at each point along the cable and antenna system length.

  • Cable Loss function measures insertion loss of the cable system over a given frequency range.

  • USB communication ports for connection to PC, field sensors and storage devices.

 

Applications

  • Worldwide Cellular and PCS/DCS systems

  • Supports measurement of CDMA, GSM, TDMA and AMPS modulation

  • Broadcast, Government, Tactical Military, Microwave, Paging, Public Safety, Trunking, WLAN and WLL, and TETRA

     

SPECIFICATION                                         SA-3600XT                               SA-6000XT

Frequency Range                                      25 - 3600 MHz                          23 - 6000 MHz

 

Frequency Resolution                          25 kHz;  25 - 800 MHz         25 kHz; 25 - 800 MHz

                                                               50 kHz;  800 - 2500 MHz     50 kHz; 800-2500 MHz

                                                             150 kHz;  2500 - 3600 MHz  150 kHz; 2500-6000 MHz

 

Power Measurement                                                                    YES

 

Return Loss                                                                               0 to -60dB

 

Test Port                                                                      N-type Female Connector

 

Impedance                                                                                     50 Ω

 

Speed                                                        1 multi-frequency scan (238 points) /2 seconds

                                                                   1 multi-frequency scan (475 points) /3.5 seconds

                                                                    1 multi-frequency scan (949 points) /6 seconds

 

Trace Resolution                                                 238 (default), 475, or 949 per trace

 

Storage Capacity                                                 Thousands of setups and traces

 

Immunity to Interfering Signals                Rejects on-frequency signals up to + 13 dBm

 

Maximum Input Signal                                                             +22 dBm

 

Data Transfer                                                               [Sensor] - USB 2.0 Type A

                                                                                          [PC] - USB 2.0 Type B

 

Internal Time                                                Rechargeable Lithium-Ion battery, 5-hr min

                                                                operating time. Auto shut-off conserves battery life.

 

External DC                                                                        9-15 VDC fused, <3A

 

External AC                                                                 100 to 240 VAC @ 50-60 Hz

                                                                                        AC/DC adapter required

 

Operating Temperature                                              10° to 50°C (-14 to 122 °F)

 

Storage Temperature                                               -40 to +80°C (-40 to +176°F)

 

Humidity (Non-condensing)                                                        95%

 

Altitude                                                                          Up to 15,000 feet (4572m)

 

Dimensions                                                            10.5" x 8.4" x 3.3"(265 x 212 x 83 mm)

 

Weight                                                                                     5.5lbs (2.5Kg)

 

Upgradeable                                             YES, to SA-6000XT                            NA

 

Compatible Device                                5012B, 5014, 5015, 5016B, 5017B, 5018B, 5019B, 7020

Customer who bought this item also bought...

5012D, 5016D, 5017D, 5018D, 5019D

WIDEBAND POWER SENSOR

7022 

STATISTICAL POWER SENSOR

7020 

POWER SENSOR

5010B, 5014B

DIRECTIONAL POWER SENSOR

Calibration Kit

Standard Accessories

Soft Carrying Case

USB Interface Cable

AC Adapter

(15 Vdc Output)